OCHFA10 Long-Line Endoscope Camera Module
Product Videos
Downloads
OCHFA10 Long-Line Endoscope Camera Module

Note: the OCHFA10 image sensor is purchased externally. The complete long-line probe, cable processing, probe assembly, tuning and final testing are all carried out in-house. The probe can be packaged as a 1.6-2.0 mm outer-diameter long-line module; every module can be paired with a UVC image-processing decoder board, and full-process custom development is supported. IMPORTANT: the sensor itself is not autoclavable, and the original manufacturer has not performed fail-safe validation for Class III life-critical medical devices. For human clinical equipment, the customer must complete device-level sterilisation, performance, safety and regulatory certification. We supply the imaging module hardware only.
Ultra-compact CubeChip imaging solution enabling a 1.6-2.0 mm probe diameter — Built on the OmniVision OCHFA10 OVMed® chip-scale packaged sensor with a 1/18" optical format and PureCel®Plus-S back-illuminated pixel technology. The chip is extremely small, allowing a probe outer diameter of 1.6-2.0 mm for entry into the narrowest cavities. A native diagonal field of view of 120°±3° and a 5-50 mm depth of field deliver clear close-up endoscopic imaging, making it ideal for single-use endoscope development. Enhanced near-infrared (NIR) sensitivity, zero blooming, low noise and low power consumption.
Analogue VOUT long-line transmission up to 4 m with custom cable options — VOUT analogue video output drives up to 4 m; cable length can be specified from 10 cm to 4 m and cable diameter is made to order. We perform impedance matching and signal-integrity tuning on the long analogue line to reduce attenuation, interference and noise. The module pairs with a UVC image-processing decoder board that converts the analogue signal to digital video, so a complete endoscopic system can be built quickly with less back-end development work.
Full-dimensional customisation of the mechanical structure
Probe housing can be a stainless-steel tube or a copper tube, and the length of the rigid metal section is made to order. The probe tip can be polished and chamfered to reduce the risk of scraping during insertion and improve safety.
Total cable length, cable diameter, tail connector type and cable exit direction can all be tailored to the complete device.
Compatible with rigid, flexible and spring-tube endoscope structures, and particularly well suited to single-use endoscope designs.
Optics and illumination made to order — Lens FOV and depth of field can be adjusted to project requirements. The complete LED lighting set is customisable, including LED count, LED type selection and series or parallel circuit topologies. Together with the back-end circuitry the chip supports a pseudo-global-shutter LED mode for strobed LED illumination, suppressing motion blur and improving imaging under intra-cavity LED lighting.
Rich built-in image controls for flexible tuning — Register configuration over the SPI serial interface; linear mode and two Staggered-HDR interleaved high-dynamic-range exposure modes with independent long/mid exposure control for high-contrast cavities; multiple cropped resolutions and software reset; VTS frame-timing adjustment for pseudo-global-shutter LED operation; independently configurable exposure time and gain, making it easy for customers to develop AE/AGC algorithms.
Complete in-house production and delivery system — The sensor is purchased externally; probe assembly, cable crimping and soldering, signal tuning, burn-in and final testing are all performed in-house. We provide requirement assessment, sample prototyping, and small- to high-volume delivery, and can support customers with SPI register tuning for fast system integration.
1. Core imaging sensor parameters (OCHFA10)

2. Mechanical customisation parameters

3. Optical & illumination customisation parameters

4. Hardware integration capability
Image output: VOUT analogue output, compatible with UVC image-processing decoder boards for analogue-to-digital conversion and rapid assembly of a complete endoscopic imaging system.
Long-line optimisation: impedance matching on long analogue cables reduces interference and noise and keeps the image output stable.
Control: SPI interface lets the host read and write registers for exposure, gain and mode-switch tuning.
5. Core product functions
Multi-resolution readout: 700×700 full-frame output plus 600×600 and 400×400 cropped window output. Cropped modes raise the frame rate and reduce motion blur to match different system bandwidths.
High-dynamic-range HDR imaging: two Staggered-HDR interleaved exposure modes (default-offset and fixed-offset), with independent exposure time and gain for the long and mid exposure channels, improving imaging in cavities with strong light/dark contrast.
Pseudo-global-shutter LED mode: configurable VTS vertical timing matches strobed LED illumination to produce a pseudo-global-shutter effect, effectively suppressing rolling banding and motion blur under LED lighting — highly practical for intra-cavity endoscopic illumination.
Flexible exposure and gain control: exposure time and gain can be set independently for the long and mid channels; software reset is supported; registers can be updated during vertical blanking, which helps in developing AE and AGC algorithms.
Analogue long-line transmission: native drive distance up to 4 m; after cable impedance tuning, stable analogue video output is maintained over 10 cm to 4 m cables, with a UVC decoder board converting it to digital video at the back end.
eFuse support: one-time programmable eFuse for storing chip configuration and calibration parameters.
※ Typical Applications
IMPORTANT: the original manufacturer of the OCHFA10 has not performed fail-safe validation for Class III life-critical medical devices. For human clinical equipment, the customer must complete device-level performance, safety and regulatory certification. We supply the imaging module hardware only.
✅ Medical applications
1. Human clinical endoscopy (primarily single-use endoscopes)
Compatible devices: bronchoscopes, urological endoscopes (cystoscopes, ureteroscopes, pyeloscopes), ENT endoscopes (otoscopes, rhinoscopes, laryngoscopes), dental intraoral cameras, hysteroscopes and other ultra-small-diameter endoscopes. Departments: respiratory medicine, urology, ENT, dentistry and gynaecology. Product formats: focused on single-use and semi-reusable endoscope designs; compatible with rigid, flexible and spring-tube endoscope structures. The 1.6-2.0 mm probe diameter suits narrow-cavity interventional inspection.
2. Veterinary medical endoscopy
For small-animal pet hospitals and livestock veterinary equipment; used to examine animal ear canals, respiratory tracts, urinary cavities and the oral cavity. Suitable for ultra-thin veterinary bronchoscope and urological endoscope imaging modules, and for single-use veterinary endoscopic products.
✅ Industrial inspection
Internal inspection of small-bore tubes, examination of precision part cavities, detection of defects in tiny gaps, observation of fine piping and micro-mould cavities, micro-component defect detection, and special portable ultra-thin endoscopic inspection equipment.
✅ Product format compatibility
This OCHFA10 long-line endoscope module can be packaged with a 1.6-2.0 mm probe diameter and a custom 10 cm to 4 m cable, and every module can be paired with a UVC imaging decoder board.
Rigid-tube option: stainless-steel or copper rigid probe, suited to rigid access routes such as ENT and oral applications.
Flexible / spring-tube option: spring-sheathed long-line structure for bronchoscopy, urology and other scenarios requiring flexible entry into narrow cavities, especially single-use flexible endoscopes.
✅ Product summary
Based on the 0.49 MP OVMed® ultra-compact imaging chip, this OCHFA10 long-line endoscope module achieves a 1.6-2.0 mm probe diameter, natively supports analogue long-line transmission up to 4 m, and offers Staggered-HDR high-dynamic-range imaging and a pseudo-global-shutter LED mode. It covers three major directions: single-use human clinical endoscopy, veterinary endoscopy and precision inspection of small industrial cavities. Rigid, flexible and spring-tube endoscope formats are supported, fitting bronchoscopes, urological endoscopes, otoscopes, oral cameras and other ultra-thin endoscopic devices.
✅ Customisation and engagement
The OCHFA10 image sensor is purchased externally; cable processing, probe assembly and full testing are completed in-house. Customers can specify probe diameter, total cable length, metal tube material and length, lens FOV, LED configuration and decoder-board requirements. We provide solution assessment, sample prototyping and volume supply.
Service Advantages
- Full-chain technical service capability covering image processing, hardware and application layers, with SDK and API protocols;
- Fine medical-grade and industrial-grade image tuning services, plus function and PCBA customization;
- Fast response: technical support and sales centers in East China (Suzhou) and South China (Shenzhen), serving the Yangtze River Delta and Pearl River Delta nearby;

Over 20 years of image-processing experience and more than 10 years as a core supplier of endoscope image-processing decoder boards, with technical-support experience serving 100+ endoscope companies;

-
Full-chain technical service
Covering endoscope image processing from hardware to the application layer;

-
Cross-platform coverage
Full-chain customization from decoder board to mainboard to APP, covering Windows, Android, Linux and iOS as well as ARM and x86 platforms;